CONTROL TECHNOLOGY FOR FXL

Pole reversal controllers from the FXL-C family not only reliably control our FXL magnetic chucks, but almost all electro-permanent magnet systems on the market. Input voltages of 100-500 VAC / 50-60Hz and matching modulated, pulsed output voltages and pulse powers of up to 24 kVA are unique key data which are only required under extreme conditions, but ensure maximum stability in normal use. FXL-C is available from a simple, handy table-top unit to a control cabinet version for large-scale applications; autonomous from hand-operated, part-connected with feedback to the machine to full integration into the machine control for automated applications.


 

We build FXL-CT table-top units for a maximum of 2 channels without preselection, they can be used to control magnetic chucks up to a total area of approx. 1.2m2 can be controlled.

FXL-CT is designed as a table-top unit or to be attached to the machine wall by means of the magnetic feet on the back. It is operated directly on the machine.

Function
• Magnetisation in 4 holding levels
• Pulse release cycle
• Feedback via double LED signals
• Machine sensing clamped via NO contact possible

Technical Data
• Input voltage 100-500V AC
(standard 360-440 VAC / 50-60Hz)
• Output voltage 100-500V DC
• Mains cable 3m/4mm2
• Mains plug CEE 32A
• Protection class I
• Protective class IP65
• Back-up fuse C 16 - C 32 A
(depending on the power of the connected system)
• Output cable 6m 4mm2 4 PIN FEME 28mm

Datenblatt

 

 


FXL-C control units in the control cabinet version control magnetic clamping systems from very small to very large, control is via an FXL-HB manual control unit or automated/integrated via the machine control/PLC.

Function
• Group formation/preselection
• Magnetisation in 4 holding levels
• Pulse release cycle
• Feedback via double LED signals
• Machine sensing clamped via NO contact possible
• Connection via machine PLC possible

Technical Data
• Input voltage 100-500V AC
(standard 360-440 VAC / 50-60Hz)
• Output voltage 100-500V DC
• Mains access and load output via terminal blocks
(also with cable and plug depending on integration)
• Protection class I
• Protective class IP54
• Back-up fuse C 16 - C 32 A
(depending on the power of the connected system)

Datenblatt